Boiler Parts. Get A New Boiler, Next Day For A Fixed Price. Marco Spare Parts. Marco Ecoboiler (Tap Model) T10 1000661 Water Boiler Spares The model number of your Marco water boiler will be located on a data sticker. Fault Finding Procedure Warning! If the problem cannot be resolved and the appliance is under warranty, then please contact the manufacturer of the Holiday Home, via the point of sale, if the boiler was an original fitment. basket worth: £16,307.28, review your basket » If you would like a gas safe register engineer to call out due to your Baxi MainEco boiler not working then please give us a call and we will come out to your property by calling the number above 07720 247 247. Got a problem with your Baxi MainEco Boiler, is it a combi boiler or a system boiler. Results 1 - 5 of 5. To change a part on the Baxi MainEco can be done very quickly just like finding what the problem is with the boiler within the fault finding codes. monday - friday 9am - 5pm. Follow instructions carefully. £38.00. A: Outside of the US a 2.8kW machine needs single phase 13Amp, a 5.6kW needs single phase 30Amp, a 8.4kW needs three phase 48Amp. www.thewaterwarehouse.co.uk. Using the special mode means it will take about 10 seconds for water to … Service Manual 1000660 T5 1000661 T10 1000665 PB5 1000666 PB10 Ecoboiler Polish 021111 Page … ABOUT Marco; PARTNERS; FAQs; Close; Products. Page 4 Troubleshooting: The … When having a repair done after this date, the new pump that will be used to replace the original pump will then have to be upgrade to the new ERP regulation which includes extra wiring to the PCB. ECO Boilers. The only regular maintenance required is occasional de-scaling. Spare Parts List 22 . Marco Spares Service & Repair; Schools, MOD and Authorities; Menu. Sign in . Easy to descale and service. At present, if you have had you Baxi MainEco fitted before 16th September 2015, you are most like going to have a central heating pump fitted without the ERP. The Marco T10 eco-boiler is ideally situated on domestic and commercial kitchen counter tops. Marco Ecoboiler WMT5 Pdf User Manuals. Probable cause: No ignition or flames don’t start with ignition, presence of flame but insufficient ionisation. Economy Boilers. Set your main menu in Appearance > Menus. ECO Boilers. Any boiler even if it is the Baxi MainEco MUST NOT be repaired by a non-gas safe engineer in is very important that who ever come to repair you boiler must carry a gas safe ID. Ecoboiler T5; Ecoboiler T10; Ecoboiler PB5; Ecosmart PB10 Hi Deck; ECO range/ Undercounter. Plumbs directly into a mains supply. Upper Tap Assembly . Manual fill variants available. Home.  Drain water from machine, drain hose is located at the base of the machine, which is accessible by removing right side panel. The manufacturer and Morco will then arrange for an engineer to visit and resolve the problem. TEM PERATURE CALIBR ATION 3.3.1 Eco Boiler version The Ecoboiler control PCB (1600345) has the ability to have the desired set-point temperature at whatever setting is required. Home. Your boiler will feature a pressure gauge that can be used to read the boiler pressure. ECO Boilers. Marco Eco Boiler PB10. It is a prohibited to work on a gas appliance unless you have proper qualifications (Gas Safe Registered). 8000270 or similar. 1500985. Descaling procedure 17 4.9. Registered Address: Morco Products Ltd, Morco House, Upper Tap Assembly . Perfect for a range of catering locations, including hotels, kitchens, offices, coffee shops and canteens, the Marco 10Ltr Ecoboiler under counter Water Boiler UC10 is exceptionally compact, highly stylish and energy efficient. Menu. Upper Tap Assembly . £38.00. Just below are common questions and answers that you may be looking for which is the reason you have most likely landed on this page to start with before you call an emergency plumber that is gas safe. It is important that you find this information as different models will comprise of different spare parts. Martin Smith an emergency plumber and a gas engineer explains everything you need to know and how easy it can be to diagnose what the problem before you call a gas safe registered emergency plumber out. Controlled electronically and made with 95% recyclable material. The fault finding codes and diagram is place in-between the unit that clips off and the boiler. Go. Marco's Ecoboiler range is designed to save space & money. Tank Components 16 4.8. MIX UC3; MIX UC3 – 110v; MIX UC8; MIX UC8 – 110v; MIX 1 Button Font; MIX 3 Button Font; MIX PB3; MIX PB3 – 110v; MIX PB8; Drip tray; ECO range/ Countertop. This depends on a number of factors. » To check these out the gas safe engineer will need to check the adequate draw of the chimney connection or replace gas air unit. Got a problem with your Baxi MainEco Boiler, is it a combi boiler or a system boiler. Sign in . water at work. Perfect for a range of catering locations, including hotels, kitchens, offices, coffee shops and canteens, the Marco 10Ltr Ecoboiler Tap Water Boiler T10 is exceptionally compact, highly stylish and energy efficient. The boiler’s pressure should start to rise, and you should turn the tap clockwise again when it reaches around 1.5 bar. Sign in. Page 16 4.9. Wiring Diagram 1000661 Ecoboiler T10 19 4.11. Butterfly Element 2.8kw. Miscellaneous > Several possible cause and can be checked by using special tools supplied by a gas engineer. 3.3. 2100155. To this end we offer: Warranty If the problem cannot be resolved and the appliance is under warranty, then please contact the manufacturer of the Holiday Home, via the point of sale, if the boiler was an original fitment. ECO Boilers. Marco Tap handle assembly Add to basket Available. Features. Get a fixed price in 60 seconds; Gas Safe installation within 24 hours; With 0% APR for 24 months; Show More. Search. ECO Boilers. £38.00. For a gas safe registered engineer to work on the boiler in question, he/she does not have to have the Baxi MainEco training apart from a gas safe ID but it does help if the engineer in question has experience on the boiler. Marco Spares Service & Repair; Schools, MOD and Authorities; Menu. Standard. water coolers. Boiler Parts. Filter Showing 1-24 of 25 item(s) Relevance. Looking for the fault finding codes for the boiler and wonder what the flashing lights are below, firstly it is always important not to take the cover off as this MUST only be done by a gas safe engineer.  Use ScaleKleen, Marco part No. Probable Cause: Non existing or insufficient circulation, sensors badly connected, no air supply or insufficient, no flue gas flue or insufficient. Fax Hotline - 01482 212 869, Large stock of spare parts; even for obsolete appliances, Model Number of the Appliance - e.g. Search. Offering high quality performance without high energy bills, the Marco Water Boiler EcoBoiler, is an ideal energy saving addition to any professional catering environment. Marco boilers and brewers deliver excellent beverage experiences around the world. Parameter error could be pad connection of safety parameter not found and will need to be check via the wiring by a gas safe register engineer. Mix Range. Ecoboiler countertop tap boiler. By diagnosing the problem by using the leaflet, you can then get further advice from a gas safe engineer that has experience when it comes to the Baxi MainEco. Boiler Parts. Energy efficient water boiler with a compact footprint. Water Boilers. lines open . ABOUT Marco; PARTNERS; FAQs; Close; Products. Relevance Name, A to Z Name, Z to A Price, low to high Price, high to low 24 12 24 36 Show all Available. If the needle is anywhere below 1 then the pressure is too low. If your lucky, you can find an engineer that carries these parts in question, he will come along to your property and fit it well making a complete diagnostic but in most cases at present this will be hard to do. You have 348 items in your T10. Wiring Diagram 1000665 Ecoboiler PB5 20 4.12. £38.00. Marco Tap handle assembly Add to basket Available. Boiler Parts. Page 7: Technical Data 4. Technical Data: 4.1. 0 Basket. Marco Element 2.8kw 230v Butterfly Add to basket Available. Search. 2100155. Marco 5Ltr Ecoboiler Wall Mount Tap Water Boiler WMT5 - Perfect for a range of catering locations with limited space including hotels hospitals nursing homes offices canteens and other small sites. Morco are committed to supporting their products in the field whether they are in or out of warranty. Marco T5 Ecoboiler - 5 litre Tap dispense atmospheric commercial water boiler. Check out our detailed guide on what to do if your combi boiler loses pressure for more advice. Wiring Diagram 1000660 Ecoboiler T5 18 4.10. Fan fault. According to the GB law gas boilers are falling under 'controlled service' appliance. Ecoboiler T5 1000660. 2100155. COLD/SPARKLING. Emergency Plumber © 2010 - 2016 © All Rights Reserved, central heating pump fitted without the ERP. proceed to checkout », Forgotten your password? Fault Code Possible Cause; F.1: Lack of gas, a fault with the ignition or flue – may need to adjust the gas valve or replace a defective electrode lead. The PCB is already ERP ready and is only waiting for the extra connection. Sign in. Should you run the boiler in eco-mode? To check these out the gas safe engineer will need to check Vent, water pressure, cleanness of heat exchanger, circulation, sensors, air and gas flow (Replace seals). Get a fixed … The gas safe engineer will then explain if this is the type of emergency that can be done there and then are or it may need a special part to be supplied and then fitted. As I am writing this article, at present all we can say is parts don’t seem to be available as the boiler is so new but some technical guys from Baxi would say the most expensive part should come within the region or £200 for example the all-in-one fan/air unit, PCB and gas valve. The model number of your Marco water boiler will be located on a data sticker. D61B, D61E, G11E, F11E, F11EL, FEB24E/ED/ED3* or GB24/GB24 SII, Description of the problem - e.g. Search. This energy saving Marco Eco-boiler offers outstanding value for money. FRIIA C; FRIIA C (Tall) FRIIA CS; FRIIA CS (Tall) Hot/Cold/Sparkling. Relevance Name, A to Z Name, Z to A Price, low to high Price, high to low 17 12 24 36 Show all Available. View online or download Marco Ecoboiler WMT5 Service Manual This only includes majority of the faults and not the faulty expansion vessel. Home.  Remove lid located on the top of machine. Mix Range. A large proportion of problems can be cured by the above information sheets. Upper Tap Assembly . Boiler pressure is a measurement of the pressure of the hot water passing through the central heating system. If there is an issue with your boiler and you need help contact customer service team immediately. ECO Boilers. If you would like any help locating the correct spare, please contact our sales team on 01454 620500. 0 Basket. Like most boilers, if your not a gas engineer it is very hard to know what the problem is. Riverview Road, Beverley, East Yorkshire, HU17 0LD, Sales Hotline - 01482 325 456 Commercial water boiler. Available. Marco Ecoboiler T10. COLD/SPARKLING. To check these out the gas safe engineer will need to check wiring, earth, condition of burner, gas valve is fully open and supply pressure, purge gas supply to remove air, operation and setting of gas valve unit, check the air and gas inlet flue is not blocked, replace ignition. Marco Beverage Systems manufacture and test to ISO9002:2000 standard. Marco Ecoboiler (Tap Model) T5 1000660 Water Boiler Spares. The manufacturer and Morco will then arrange for an engineer to visit and resolve the problem. 0800 644 4000 . As long as the person repairing the job in question has enough experience with the MainEco boiler then the should be no reason in most cases that the job is done within 2-hours. ECO Boilers. Warning! ECO Boilers. Star Rating. Hot/Cold/Sparkling Water. appliance fails to ignite or central heating works but no hot water, The "fault code" if the appliance has an LCD display. Sign in . £38.00. FRIIA HC – 110v; FRIIA HC Plus – 110v; FRIIA HCS – 110v; FRIIA HCS Plus – 110v; Close; Water Boilers. These codes below will go in order with the lights flashing in red. 2100155. Filter Showing 1-24 of 34 item(s) Relevance. If you are a gas safe register engineer and have any experience with the Baxi MainEco then please feel free to register your detail at the plumbing register. A speedy resolution is assisted by the provision of the following key information: Out of Warranty If the appliance is out of warranty, then we suggest you read the relevant information sheet for the relevant appliance. In September 2014 the release of the Baxi MainEco Combi & System had finally landed and what a great boiler it is made out to be but how easy is it to maintain. Page 6 • Do the same action with the other font if needed. Catering Equipment Featured Products. If the solution is not apparent then click on the "Find an Engineer" on the navigation bar for one registered by Gas Safe, to provide assistance. FRIIA C; FRIIA C (Tall) FRIIA CS; FRIIA CS (Tall) Hot/Cold/Sparkling. This water boiler is ideal for all catering requirements, ranging from hotels, restaurants and … Search. Relevance Name, A to Z Name, Z to A Price, low to high Price, high to low 24 12 24 36 Show all Available. All views above are written by Martin Smith and is only a guide and not fact, it is very important to consult a gas safe registered engineer and any work MUST not be done by anyone else other than a gas safe register engineer. It is the responsibility of the engineer that once the job has been started, the all safety precautions are taken in order to make sure the occupants are left in a safe way in accordance to the HSE and Gas Safe. Part of the Marco ecoboiler range, the Marco Countertop Ecoboiler has both automatic fill and tap dispense functions providing instant unlimited hot water from your countertop. All prices shown on this website are in GBP Sterling (£). Excellent value for money. Filter Showing 25-25 of 25 item(s) Relevance. 0 Basket. Probable cause: External draught over the boiler or defective gas air unit. At present there are no comment about Baxi MainEco Problems & Stories by fellow gas safe engineer as the boiler is so new but if you a gas engineer and have and experience with these type of boilers then please let us know via our twitter feed. Instant hot water for foodservice, catering, convenience. mains fed coolers bottled coolers. Combi Boilers; Water Heaters; Spares; Troubleshooting; Welcome to Morco Products Ltd Morco Products are specialist suppliers of their own branded LPG heating and hot water equipment which they have sold to the UK and Continental European Caravan Holiday Home and Residential Park Home industries for the last 45 years. Boiler Parts. Filter Showing 1-17 of 17 item(s) Relevance. A: In the US a 2.8kW machine needs single phase 20Amp, a 5.6kW needs single phase 30Amp. GENERAL DESCRIPTION: ECO Boiler T20-3, T20-6, T30. The T10 can supply an instant draw-off of 10 litres of boiling water. 0 Basket. Like most boilers, if your not a gas engineer it is very hard to know what the problem is. Hot/Cold/Sparkling Water. It is important that you find this information as different models will comprise of different spare parts. The guarantee on a Baxi MainEco Combi or System boiler is 3-years as long as the manufacture warrantee guidelines have been followed. Wiring Diagram 1000666 Ecoboiler PB10 21 4.13. Ideal for a range of catering locations including hotels, kitchens, offices, coffee shops and canteens, the Marco 5Ltr Ecoboiler Tap Water Boiler T5 is exceptionally compact, highly stylish and energy efficient. Home. Marco Spares Service & Repair; Schools, MOD and Authorities; Menu. Takes up to 14oz cups. Q: What is the power requirement for a Marco machine? T10. Baxi MainEco Combi & System Boiler Range Problems. Marco PB10 Push Button Water EcoBoiler by The Water Warehouse is the ideal drinking water boiler for offices, homes, and schools. More Details >> Key Benefits. Home. For any orders from outside the UK please contact Morco Products Ltd for a quote. Search. Slim, stylish & made from 95% recyclable material this range has best in class energy efficiency. Page 3 ECO BOILER VERSION 1000743 (2.8kW), 1000744 (5.6kW), 1000744US (5.6kW), 1000745 (8.4kW), 1000743A (2.8kW), 1000744A (5.6kW), 1000745A (8.4kW) Operating boiler for the first time: Setting time dispense for two left hand side pumps. If you are experiencing an issue with your boiler, this guide to common boiler problems may help you diagnose the issue before reaching for the Yellow Pages and calling in outside help for an expensive emergency service. 0 Basket. If the boiler was not an original fitment, we would recommend asking the commissioning engineer to call us in front of the boiler or reporting the issue to the point of sale. Only qualified personnel (GasSafe registered technician)can perform service, installation and repair works on Main Boilers. Also note that any work performed on the Main appliance without written permission from the manufacturer or his agent could invalidate the warranty appliance. Maximum of temperature of heat exchanger of control unit exceeded! To check these out the gas safe engineer will need to check the wiring, sensor are operating correctly and have been correctly fitted, check water pressure, cleanness of heat exchanger and circulation (direction of pump, valves). If you would like any help locating the correct spare, please contact our sales team on 01454 620500. Login | Register | Basket: Item(s) £0.00. Sensor not or badly connected, insufficient or water circulation direction reversed sensor fault. Register Now », Hydraulic Assembly Repair Kit Instructions, GB24 Frost Damage - Spare Part Identification. The Marco T5 Auto Fill Ecoboiler is a slimline 5 litre capacity commercial water boiler for small to medium size caterers, perhaps with limited space but who still require an efficient, reliable machine that will provide many years of trouble-free service. ABOUT. During manufacture of the PCB it is set to the default temperature of around 90°C. Ignition Fault and flame won’t start. Just like any boiler, it has to have a clean up, some engineers will pass the boiler without a service if the readings come out as clean enough. To get the most of the guarantee, it must be seen as reasonable such as the boiler was to have a service once a year. The WMT5 is exceptionally compact highly stylish and energy efficient. water coolers accessories water filters and taps. Marco Spares Service & Repair; Schools, MOD and Authorities; Menu. Troubleshooting – Diagnostic guide 15 4.7. The Fix: Locate the filling loop (usually underneath your boiler) and turn the small tap counter-clockwise. Descaling Procedure: Isolate machine from power supply. Marco Spares Service & Repair; Schools, MOD and Authorities; Menu. Search . Should the boiler pressure drop too low then the central heating will fail to work. Sensor, temperature or flow fault. Eco-Boiler is ideally situated on domestic and commercial kitchen counter tops, G11E, F11E, F11EL, *! Online or download marco Ecoboiler WMT5 Service Manual marco Spares Service & Repair ;,. When it reaches around 1.5 bar on what to do if your combi boiler loses pressure for advice! Of your marco water boiler for offices, homes, and Schools Warehouse is the ideal drinking boiler! In red a 2.8kW machine needs single phase 30Amp ; Menu DESCRIPTION: ECO boiler T20-3,,. Spare, please contact our sales team on 01454 620500 marco water boiler for offices homes! Boiler for offices, homes, and Schools on a marco eco boiler troubleshooting sticker machine single... Information sheets check the adequate draw of the faults and not the expansion! Need help contact customer Service team immediately to know what the problem - e.g 17 item ( s ).. Pressure for more advice and Morco will then arrange for an engineer to visit and resolve problem... Falling under 'controlled Service ' appliance manufacture and test to ISO9002:2000 standard Hydraulic Assembly Repair Kit,. Push Button water Ecoboiler by the water Warehouse is the power requirement for a quote the please! Most boilers, if your combi boiler or a system boiler too.. Plumber © 2010 - 2016 © all Rights Reserved, central heating system is too low, DESCRIPTION the! Font if needed controlled electronically and made with 95 % recyclable material what is the ideal water... Review your basket worth: £16,307.28, review your basket worth: £16,307.28, your! The extra connection: External draught over the boiler ’ s pressure should start to rise, you. Arrange for an engineer to visit and resolve the problem single phase 20Amp, a 5.6kW needs single 30Amp. Checkout », Hydraulic Assembly Repair Kit Instructions, GB24 Frost Damage - spare Part Identification flashing in.! Several possible cause and can be used to read the boiler pressure ) and turn the tap... Number of your marco water boiler will feature a pressure gauge that can be checked by using special supplied... To read the boiler pressure view online or download marco Ecoboiler WMT5 Service Manual Spares... Tools supplied by a gas appliance unless you have proper qualifications ( gas Safe Registered ) a... Fault finding codes and diagram is place in-between the unit that clips off and the boiler pressure is a of! ’ s pressure should start to rise, and Schools check the adequate draw of the chimney connection replace...: what is the power requirement for a Fixed Price reaches around bar., convenience: what is the ideal drinking water boiler for offices, homes, and you need contact! - spare Part Identification the top of machine prohibited to work on a sticker! T10 can marco eco boiler troubleshooting an instant draw-off of 10 litres of boiling water gas Safe ). Contact our sales team on 01454 620500 to ISO9002:2000 standard water passing through the heating! Check these out the gas Safe engineer will need to check the adequate draw of the chimney connection replace... Will go in order with the other font if needed, T20-6, T30 PCB is already ready... Cause: External draught over the boiler pressure drop too low item ( s Relevance. Range has best in class energy efficiency & money foodservice, catering,.... Safe engineer will need to check these out the gas Safe Registered ) of different spare parts majority the... Erp ready and is only waiting for the extra connection and resolve the problem &! Comprise of different spare parts Spares Service & Repair ; Schools, MOD and Authorities ; Menu of 25 (... Will be located on the top of machine © 2010 - 2016 © all Rights Reserved, central pump! Small tap counter-clockwise on domestic and commercial kitchen counter tops detailed guide on what to do if your a! That clips off and the boiler or a system boiler spare Part Identification the field whether they are or. Water for foodservice, catering, convenience phase 20Amp, a 5.6kW needs single phase 30Amp SII, of! About marco ; PARTNERS ; FAQs ; Close ; Products to ISO9002:2000 standard your marco water boiler for offices homes... Is set to the default temperature of around 90°C, T30 excellent Beverage experiences around the world counter tops efficiency... Pcb is already ERP ready and is only waiting for the extra connection Products in the whether... The tap clockwise again when it reaches around 1.5 bar 17 item ( s )...., review your basket » proceed to checkout », Hydraulic Assembly Repair Kit Instructions, GB24 Damage. Cause and can be checked by using special tools supplied by a gas engineer is. Plumber © 2010 - 2016 marco eco boiler troubleshooting all Rights Reserved, central heating system T10 eco-boiler ideally... The central heating system Ecoboiler T10 ; Ecoboiler PB5 ; Ecosmart PB10 Hi Deck ; ECO range/ Undercounter locating... All prices shown on this website are in GBP Sterling ( £ ) FRIIA! Litres of boiling water gas Safe engineer will need to check these out the gas Safe Registered ) check our... Water circulation direction reversed sensor fault measurement of the hot water for foodservice, catering convenience... For more advice finding codes and diagram is place in-between the unit clips... Finding codes and diagram is place in-between the unit that clips off and the boiler a needs... Page 6 • do the same action with the lights flashing in red for offices,,. Underneath your boiler and you need help contact customer Service team immediately Hi Deck ; ECO Undercounter... Kitchen counter tops the PCB is already ERP ready and is only for... Other font if needed as the manufacture warrantee guidelines have been followed and not the faulty expansion vessel above sheets. T20-3, T20-6, T30 ( gas Safe Registered ) to read the boiler your basket » proceed checkout... And diagram is place in-between the unit that clips off and the boiler instant draw-off 10! Out of warranty Button water Ecoboiler by the water Warehouse is the power requirement for marco. Pressure for more advice & Repair ; Schools, MOD and Authorities Menu. Beverage Systems manufacture and test to ISO9002:2000 standard © all Rights Reserved, heating. Best in class energy efficiency basket Available is only waiting for the extra connection be cured by water... A combi boiler or defective gas air unit other font if needed money... • do the same action with the lights flashing in red, and should! A New boiler, is it a combi boiler or defective gas marco eco boiler troubleshooting. Team on 01454 620500 Service & Repair ; Schools, MOD and Authorities ;.... Draw-Off of 10 litres of boiling water DESCRIPTION: ECO boiler T20-3, T20-6,.. Friia CS ( Tall ) FRIIA CS ( Tall ) FRIIA CS ; FRIIA C ; CS. Place in-between the unit that clips off and the boiler pressure drop too low then the central heating fitted. Around the world general DESCRIPTION: ECO boiler T20-3, T20-6, T30 this only includes majority the. The ERP 1 then the central heating pump fitted without the ERP of 25 item s! Gas air unit the ERP the manufacturer and Morco will then arrange for an engineer to visit and the. Single phase 30Amp by using special tools supplied by a gas appliance unless you have proper qualifications ( gas Registered..., please contact our sales team on 01454 620500 is anywhere below 1 then the pressure the! Best in class energy efficiency Morco will then arrange for an engineer to visit and resolve the problem -.... The problem as the manufacture warrantee guidelines have been followed, FEB24E/ED/ED3 * GB24/GB24. Repair Kit Instructions, GB24 Frost Damage - spare Part Identification range is designed save..., stylish & made from 95 % recyclable material this range has best in class energy efficiency problem e.g. The water Warehouse is the ideal drinking water boiler will feature a pressure gauge can... Same action with the lights flashing in red is it a combi or. Locate the filling loop ( usually underneath your boiler will feature a gauge. Out the gas Safe engineer will need to check the adequate draw of the pressure of faults! If there is an issue with your Baxi MainEco combi or system boiler start to rise, and you turn! Reserved, central heating system designed to save space & money passing through the heating. Save space & money GB law gas boilers are falling under 'controlled Service ' appliance possible and... Circulation direction reversed sensor fault if needed best in class energy efficiency are committed to supporting their Products the! During manufacture of the hot water passing marco eco boiler troubleshooting the central heating system appliance! To do if your not a gas appliance unless you have 348 items in your basket proceed... Clockwise again when it reaches around 1.5 bar out our detailed guide on what do! Fix: Locate the filling loop ( usually underneath your boiler and you help. ( Tall ) Hot/Cold/Sparkling water Ecoboiler by the water Warehouse is the power requirement for a marco machine ;... Reserved, central heating pump fitted without the ERP falling under 'controlled Service ' appliance: No ignition flames! Gas appliance unless you have proper qualifications ( gas Safe Registered ) from outside the please.: in the US a 2.8kW machine needs single phase 30Amp when it reaches around 1.5 bar brewers! To do if your not a gas engineer it is a prohibited to work Spares &!, DESCRIPTION of the faults and not the faulty expansion vessel basket » proceed to »... Is place in-between the unit that clips off and the boiler pressure pressure should start to,! Hard to know what the problem is finding codes and diagram is place in-between unit.